beautypg.com

Cisco 3800 Series User Manual

Page 55

background image

Power Connections

25

Connecting Cables to Cisco 3800 Series Routers

OL-5970-02

Caution

Dual sources with opposite-polarity grounding damage equipment.

In

Figure 16

, either the positive source terminal or the negative source terminal is tied to ground

.

Figure 16

Connecting to One Source Only—Source A or Source B

In

Figure 17

, source A and source B share common negative terminal connections.

Figure 17

Connecting Source A and Source B with Common Negative Terminals

In

Figure 18

, source A and source B share common positive terminal connections. This configuration is

allowed only if Va equals Vb (within 0.25 V).

Caution

If source A and source B are wired with common positive terminals and their voltages are unequal by
more than 0.25 V, the higher-voltage source can discharge into the lower-voltage source through the
negative terminals. Excessive discharging currents through these terminals can actuate one or both of
the dual- input DC power supply’s internal A– or B– fuses, resulting in lack of redundancy or system
failure. When source A and source B are within 0.25 V, discharge current is minimal.

A-

127037

A+

B+

B-

+

A-

A+

B+

B-

+

A-

127039

A+

B+

B-

Va

Vb

+

+