ARCMASTER 401S POWER SOURCE
Manual 0-5345
3-15
INSTALLATION, OPERATION AND SETUP
3.12 Special Function
Encoder Control
Process Selection Button
Remote Control
Contactor Control
Parameter Selection
Button
Art # A-12547_AB
Figure 3-9
Gouging and 6010 Vertical Down
There are two special functions that can be accessed by pressing the selection button for 2 seconds: Gouging
and 6010 Vertical Down.
Gouging - In Stick mode hold the process Selection Button for 2 seconds and the LED will blink indicating
Gouging mode is enabled.
6010 Down - In 6010 mode hold the process Selection Button for 2 seconds and the LED will blink indicating
6010 Vertical Down mode is enabled.
Lock/ Unlock User Interface (UI)
UI Lock Function can be enabled or disabled by pressing Encoder Control for 5 seconds.
NOTE
The function lock setting is saved! If the machine is switched off with the function lock activated, the
control panel is still locked when the machine is switched back on.
LED Test
Press Parameter Selection Button for 2 seconds to start LED test. The test will last for about 5 seconds. During
the test all LEDs are lit.
Display Software Version
Press Remote Control and Contactor Control buttons at the same time for 2 seconds and it will display the
software version of User Interface (UI), master and process.
Master Reset
!
WARNING
All personal settings will be lost!
The 401S can have master reset. All the jobs saved will be deleted and all parameters will be set back to factory
setting. This function is accessed by pressing Parameter Selection Button and Remote Control Button at the
same time for 2 seconds.