Gouging and 6010 Vertical Down

There are two special functions that can be accessed by pressing the selection button for 2 seconds: Gouging

and 6010 Vertical Down.

Gouging - In Stick mode hold the process Selection Button for 2 seconds and the LED will blink indicating

Gouging mode is enabled.

6010 Down - In 6010 mode hold the process Selection Button for 2 seconds and the LED will blink indicating

6010 Vertical Down mode is enabled.

Lock/ Unlock User Interface (UI)

UI Lock Function can be enabled or disabled by pressing Encoder Control for 5 seconds.

NOTE

The function lock setting is saved! If the machine is switched off with the function lock activated, the

control panel is still locked when the machine is switched back on.

LED Test

Press Parameter Selection Button for 2 seconds to start LED test. The test will last for about 5 seconds. During

the test all LEDs are lit.

Display Software Version

Press Remote Control and Contactor Control buttons at the same time for 2 seconds and it will display the

software version of User Interface (UI), master and process.

Master Reset

!

WARNING

All personal settings will be lost!

The 401S can have master reset. All the jobs saved will be deleted and all parameters will be set back to factory

setting. This function is accessed by pressing Parameter Selection Button and Remote Control Button at the

same time for 2 seconds.