beautypg.com

Arcmaster 401s power source – Tweco ArcMaster 401S User Manual

Page 29

background image

ARCMASTER 401S POWER SOURCE

Manual 0-5345

3-9

INSTALLATION, OPERATION AND SETUP

11 14 Pin Remote Control Socket

The 14 pin Remote Control Socket is used to connect Remote Control devices to the welding Power Source.

To make connections, align keyway, insert plug, and rotate threaded collar fully clockwise.

Pin

Function

Description

A

+16VDC contactor

16 VDC supply voltage for contactor. Connect A & B for

contactor enable.

B

Contactor in

Contactor input. Connect A & B for contactor enable.

C

+10VDC Remote Ctrl (Max)

10 VDC for remote potentiometer supply

D

Remote ctrl ground/common (min) Also control circuit common

E

Remote Input

0<=Vin<=10V

F

n.c.

G

Chassis ground

H

n.c.

I

n.c.

J

n.c.

K

CAN_high

CAN bus; positive signal

L

CAN_low

CAN bus; negative signal

M

Current detect relay 1

Relay contact between M & N will close while welding is active

N

Current detect relay 2

Table 3-2 14 Pin Interconnection Control Plug Configuration

12 ON/OFF Switch

This switch connects the Primary supply voltage to the inverter when in the ON position. This enables the

Power Supply.

!

WARNING

When the welder is connected to the Primary supply voltage, the internal electrical components may

be at 500V potential with respect to earth.

13 Input Cable

The input cable connects the Primary supply voltage to the equipment.