beautypg.com

Transmig 200i – Tweco 200i Multi Process Welding Inverter User Manual

Page 28

background image

TRANSMIG 200i

INSTALLATION, OPERATION AND SETUP

3-10

Manual 0-5209

17. On / Off Switch

This Single Phase circuit breaker performs a dual function.

It is used to turn the unit on/off and it will also trip in the event of a fault.

WARNING

When the front digital displays are lit, the machine is connected to the Mains supply voltage and

the internal electrical components are at Mains voltage potential.

Art # A-10422

Figure 3-4: Wire Feed Compartment Control

18. Wiredrive Motor Circuit Breaker

The 4A Circuit Breaker protects the unit from electrical faults and will operate in the event of a motor

overload.

NOTE

If a circuit breaker trips, a short cooling period must be allowed before an attempt is made to reset

the unit by pressing the circuit breaker reset button

.

19. Local / Remote Switch (located in wirefeed compartment)

The remote / local switch is used only when a remote control device (such as a TIG torch with remote

current control) is fitted to the unit via the remote control socket (item 9). When the local/remote switch is

in the remote position, the unit will detect a remote device and work accordingly. When in the local mode,

the unit will not detect the remote device and will operate from the power source controls only. Note that

the trigger will operate at all times on the remote control socket irrespective of the position of the local

remote switch (ie in both local and remote modes).

Should a remote device be connected and the remote/local switch set to remote, the maximum setting

of the power source will be determined by the respective front panel control, irrespective of the remote

control device setting. As an example, if the output current on the power source front panel is set to 50%

and the remote control device is set to 100%, the maximum achievable output from the unit will be 50%.

Should 100% output be required, the respective front panel control must be set to 100%, in which case

the remote device will then be able to control between 0-100% output.