01 scope of this manual – Tweco Ultima 150 User Manual
Page 15
Manual 0-2472
9
SECTION 2: GENERAL INFORMATION
SECTION 2:
GENERAL INFORMATION
2.01 Scope of this Manual
This manual provides operating instructions and basic
maintenance procedures for the Thermal Arc ULTIMA-
150
®
Plasma Welding Power Supply. Service of this equip-
ment is restricted to Thermal Dynamics trained person-
nel; unqualified personnel are strictly cautioned against
attempting repairs or adjustments not covered in this
manual, at the risk of voiding the warranty.
Read this manual thoroughly. A complete understanding
of the capabilities and functions of the equipment will
assure the dependable operation for which it was designed.
2.02 ULTIMA-150 Power Supply
Description
The ULTIMA-150 Plasma Welding Power Supply is one
integrated unit providing power, pilot control inverter, and
coolant recirculator. With output ranges from 0.5-15 amps
and 5-150 amps, the power supply is ideally suited for all
low current gas tungsten arc welding (GTAW) and auto-
mated welding applications. Suitable for use with all des-
ignated Thermal Dynamics plasma welding torches.
2.03 ULTIMA-150 Power Supply
Specifications
A. Input Power
200 VAC ±10%
50/60hz, 1 or 3 phase
208 VAC ±10%
50/60hz, 1 or 3 phase
230 VAC ±10%
50/60hz, 1 or 3 phase
380 VAC ±10%
50/60hz, 1 or 3 phase
415 VAC ±10%
50/60hz, 1 or 3 phase
460 VAC ±10%
50/60hz, 1 or 3 phase
575 VAC ±10%
50/60hz 3 phase (available with
optional Transformer Module
only)
B. Output Power
1. Output Amps
Range I - 0.5 to 15 amps DC Straight Polarity
Range II - 5 to 150 amps DC Straight Polarity
2. Duty Cycle
60% Duty Cycle @ 40ºC, 150 amp output
100% Duty Cycle @ 40°C, 100 amp output
3. Pilot Arc Output
2-15 amp Variable, Continuous Pilot Arc
Pilot Arc Output 100% Duty Cycle @ 40º C
C. Fuse
3A, 500V (1FU) Fuse
D. Protection Features
A number of interlocks have been to provided to assure
proper handling of fault conditions at all times.
• Coolant flow and level - Monitored and shut down
the recirculator pump when below minimum levels.
• Pump operation - System shuts down due to air in
torch leads or in the system.
• Coolant and power supply - Over temperature of the
power supply or coolant will immediately disable
the power supply output. The recirculator pump re-
mains running for system and coolant cool down.
• Plasma gas and shield gas - Both have minimum
pressure switches that disable pilot arc operation.
• Pilot arc - Always latched off in event of power sup-
ply interlock trip. The pilot must be disabled and
then re-energized to initiate the pilot arc after a fault
shutdown.
E. Gas Supply
Plasma Gas - 0.5-3.0 scfh
Shield Gas - 5.0-30 scfh
F. Coolant Reservoir Capacity
2 gallon Coolant Reservoir; Thermal Arc© Coolant
only
G. Weight
130 lbs (59 kg) - ULTIMA-150 Power Supply only
150 lbs (68kg) - shipping weight (including coolant
and torch)
H. Dimensions
18" high (457 mm) x 15" wide (381 mm) x 28.5" deep
(724 mm)