6.03 Save-Load Operation

A total number of 5 programs can be saved into the 400 TS memory.

SAVE

the Current Weld Parameters into Memory

• Press the

SAVE

button until the buzzer rings.

• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter
• After selecting the desired memory location (ie 1 to 5), press the right scroll button and the machine will give

a beep to confirm the weld parameters from the control panel are saved.

LOAD

(retrieve) a Program to Control Panel

• Press the

LOAD

button until the buzzer rings.

• Select a memory location by rotating the control knob, 1 to 5 is displayed on the meter. After selecting the

desired memory location (i.e. 1 to 5), press the right scroll button and the machine give a beep to confirm the
weld parameters are loaded onto the control panel