4.03 Weld Parameter Description
Figure 5. ArcMaster 400 TS Front Panel with Parameter Description
Parameter Description
PRE-FLOW
This parameter operates in TIG modes only and is used to get gas to the weld zone
prior to striking the arc, once the torch trigger switch has been pressed. This
control is used to dramatically reduce weld porosity at the start of a weld.
HOT START
This parameter operates in all weld modes except Lift TIG mode and is used to
heat up the weld zone in TIG modes or improve the start characteristics for stick
electrodes. e.g. low hydrogen electrodes. It sets the peak start current on top of
the
PEAK (WELD)
current.
e.g.
HOT START
current = 130 amps when
PEAK (WELD)
= 100 amps &
HOT START
= 30 amps
INITIAL CUR.
This parameter operates in
SLOPE
or
REPEAT
(4T) TIG modes only and is used to
set the start current for TIG. The Start Current remains on until the torch trigger
switch is released after it has been depressed.
UP SLOPE
This parameter operates in TIG modes only and is used to set the time for the weld
current to ramp up, after the torch trigger switch has been pressed then released,
from INITIAL CUR to PEAK or BASE current.
PEAK CUR.
This parameter sets the PEAK weld current when in
PULSE
mode.
WELD
This parameter sets the TIG WELD current in
STD
,
SLOPE
,
REPEAT
and
SPOT
modes when
PULSE
is off. This parameter also sets the STICK weld current.
BASE
This parameter sets the Background current when in Pulse TIG mode.