29
6.01 Stick Welding
• Connect work lead to negative terminal
• Connect electrode lead to positive terminal
• Switch machine on
• Set Contactor
• Connect remote control device if required
Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.
• Set
HOT START
• Set
WELD
current
Commence welding
6.02 HF TIG & Lift TIG Welding
• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine on
• Set weld current
• Connect remote control device. A remote control device is required for use during LIFT TIG and
HF TIG operation. See section 4.01, section 2 “
Remote Control Socket
”, for complete details of
the remote device.
Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.
• Set
PRE-FLOW
time
• Set
HOT START
current
• Set
POST-FLOW
time
• Set
WELD
current
• Set
POST-FLOW
time
Slope Mode Parameters if required
• Set
INTIAL CUR
current
• Set
UP SLOPE
time
• Set (WELD)
PEAK CUR
current
• Set
BASE
current
• Set
DOWN SLOPE
time
• Set
CRATER CUR
current
Pulse Mode parameters if required
• Set
PULSE WIDTH
% for
PEAK CURRENT
• Set
PEAK CURRENT
• Set
PULSE FREQ
Commence welding