beautypg.com

02 functional block diagram, 03 transporting methods, Figure 2. 400 ts model functional block diagram – Tweco 400 TS Arcmaster User Manual

Page 18

background image

11

2.02 Functional Block Diagram

Figure 2 illustrates the functional block diagram of the 400 TS power supply.

Main

Circuit

Switch

Filter

Input

Diode

Primary

Capacitor

DC Power

Voltage

Sensor

IGBT

Inverter

Thermal

Detector

To each control circuit

+/-15VDC +18VDC

+24VDC +5VDC

Troublel
Sensing

Circuit

Drive

Circuit

Torch Control

Connection

(CON1)

circuit

Current

Adjustment

Reference

Adjustment &

Mode select Switches

Panel Circuit Board

Sequence

Control

Themal

Sensor

Circuit

Main

Transformer

(PCB14)

Output

Diodes

HF-UNIT

Control

Circuit

Stick Mode

VRD

Sensing

Circuit

Lift T ig Mode

Output Short

Sensing

Circuit

Coupling

High

Coil

Frequency

Unit

Fan Control

Circuit

Gas Control

Circuit

Fan

Solenoid

Hall Current

Transformer

(HCT1)

Output

Inductor

Thermal

Detector

+

-

+

-

Input

Power

Primary
Current
Sensor

Figure 2. 400 TS Model Functional Block Diagram

2.03 Transporting Methods

This unit is equipped with a handle for carrying purposes.

WARNING 1

ELECTRIC SHOCK can kill. DO NOT TOUCH live electrical parts. Disconnect input power conductors
from de-energized supply line before moving the welding power source.

WARNING 2

FALLING EQUIPMENT can cause serious personal injury and equipment damage.

Lift unit with handle on top of case.
Use handcart or similar device of adequate capacity.
If using a fork lift vehicle, place and secure unit on a proper skid before transporting.