08 specifications – Tweco 300 ACDC Arcmaster User Manual
Page 24

18
3.08 Specifications
Parameter 300
AC/DC
Rated Output
Amperes
Volts
Duty Cycle
300
22
30%
Duty Cycle
TIG
300A / 22V @ 40%
250A / 20V @ 60%
180A / 18V @ 100%
STICK
300A / 32V @ 40%
250A / 30V @ 60%
180A / 28V @ 100%
Output Current
TIG
5 – 300 (DC)
5 – 300 (AC) @ 60Hz, 50% Cleaning
Range
STICK
5 – 300 (DC)
5 – 300 (AC) @ 60Hz, 50% Cleaning
Open Circuit Voltage
65V
Dimensions
Width
Height
Length
8.3” (210mm)
16.5” (420mm)
17.7” (450mm)
Weight
52.8 lb. 24 kg
Output @ Rated Load
Rated Input Voltage
Output Amperes
Output Volts
Duty Cycle
KVA
KW
Three-phase
300A
32V
40%
18.0
12.0
Output @ No Load
KVA
KW
0.5
0.13
Input Volts Single Phase
400V
Amperage Draw @ Rated Load
40
No Load Amps
1.6
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment
previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items. The values specified in
the table above are optimal values, your values may differ. Individual equipment may differ from the above specifications due to in
part, but not exclusively, to any one or more of the following; variations or changes in manufactured components, installation location
and conditions and local power grid supply conditions.