03 power source problems, 03 power source problems -7, Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual
Page 55

ARCMASTER 200 AC/DC
April 13, 2006
10-7
10.03 Power Source Problems
Description Possible
Cause
Remedy
1 The welding arc
cannot be
established.
A
B
The Primary supply voltage has
not been switched ON.
The Welding Power Source
switch is switched OFF.
A
B
Switch ON the Primary
supply voltage.
Switch ON the Welding
Power Source.
C Loose connections internally.
C Have an accredited Thermal
Arc Service Agent repair
the connection.
2 Maximum output
welding current can
not be achieved with
nominal Mains
supply voltage.
Defective
control
circuit.
Have an accredited Thermal
Arc Service Agent repair
the connection.
3 Welding current
reduces when
welding.
A
B
C
D
E
Loose welding cable
connections.
Incorrect welding cable size.
Improper input connections.
Poor electrode condition.
Wrong welding polarity.
A
B
C
D
E
Tighten all welding
cable connections.
Use proper size and
type of cable.
Refer to Section 2.05
Electrical Input Requirements.
Replace electrode.
Verify output torch
connections.
4 No gas flow when
the torch trigger
switch is depressed.
A
B
Gas hose is cut.
Gas passage contains
impurities.
A
B
Replace gas hose.
Disconnect gas hose from
the rear of Power Source then
raise gas pressure and blow
out impurities.
C Gas regulator turned OFF.
C Turn gas regulator ON.
D Torch trigger switch lead is
disconnected or switch/cable
is faulty.
D Reconnect lead or repair faulty
switch/cable.
Table 10-3: Power Source Problems