15 dmc-3000 gas manifold control installation, Dmc-3000 gas manifold control installation -20, Ultra-cut 200 xt – Tweco 200 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 44

ULTRA-CUT 200 XT
3-20
INSTALLATION
Manual 0-5304
NOTE
There are holes added in the rear panel for customer wiring. This, rather than the one in the CCM will be
the preferred place for customer added wiring (and strain relief) for connections to height controls, etc..
3.15 DMC-3000 Gas Manifold Control Installation
The	DMC-3000	Gas	Control	must	be	installed	in	a	suitable	location	where	it	is	easily	accessible	to	the	system	op-
erator.		The	unit	must	be	mounted	to	a	flat	horizontal	surface.		If	the	Module	is	mounted	to	any	support	subject	to	
vibration	or	motion,	the	installer	must	fasten	the	module	to	the	support	securely.
The	Module	should	be	located	as	far	away	as	possible	from	the	Arc	Starter	due	to	possible	electromagnetic	inter-
ference.		It	is	acceptable	to	locate	the	control	cable	in	the	same	track	as	the	cables	from	the	Arc	Starter	and	away	
from torch leads.
The	Module	includes	feet	which	lift	the	bottom	panel	of	the	mounting	surface.	Louvers	on	the	back	panel	of	the	
module	must	remain	unblocked,	for	the	free	passage	of	ventilating	air.
Mounting Dimensions
5.00 in
[127.0 mm]
7.08 in
[179.8 mm]
12.18 in
[309.4 mm]
11.44 in
[290.6 mm]
.30 in
[7.62 mm]
DMC-3000 Top
13.60 in
[345.6 mm]
DMC-3000 Profile
Art # A-09459