Ultra-cut or auto-cut o2 – Tweco 200 Auto-Cut User Manual
Page 32
Manual No. 0-4805 Auto-Cut 200
3-8
INSTALLATION
0 - 10 ft (0 - 3 m) Ideal
20 ft (6 m) Maximum
1/0
Ground Cable
#4 AWG Ground
Gas Control Module
Alternate location
Power Supply
‘Star’
Ground
Earth Ground
Rod
1/0 Ground Cable
CNC
Device
Torch
Cutting Table
Cutting Machine / Gantry
1/0 Work Cable
Remote Arc
Starter (RAS-1000)
1/0
Ground Cable
0 - 10 ft (0 - 3 m) Ideal
20 ft (6 m) Maximum
Gas Control Module
Power Supply
‘Star’
Ground
Earth Ground
Rod
1/0 Ground Cable
CNC
Device
Torch
Cutting Table
Cutting Machine / Gantry
1/0 Work Cable
Remote Arc
Starter (RAS-1000)
1/0
Ground Cable
Star Ground on Cutting Table / Auto-Cut W/RAS
Star Ground on Cutting Table
1/0
Ground Cable
Ultra-Cut
or
Auto-Cut O2
Note: The gas control module
can be mounted to the cutting table.
If it is, it should be grounded
directly to the star ground with
#4 AWG ground.
Note: The gas control module
can be mounted on top of the power
supply. If it is, it should be grounded
directly to the power supply with
#4 AWG ground.
Gas Control Module
Primary location
#4 AWG
Ground
#4 AWG Ground
(Factory Installed)
Art # A-08253