Connect Input Power and System Ground Cables
1. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut back
the insulation on the individual wires. Route the cable upward through the connections cover support panel
on the rear panel of the power supply.
2. Insert the individual wires into the proper lug and tighten the nut onto the wires.
3. Pass the ground and input power cables through the leads bracket as shown. Connect the individual wires as
shown. Connect the power cable ground wire to the ground terminal block.
CAUTION
The clear connections cover must remain in place.
4. If required, pass a system ground cable (F1) through the last opening in the connections cover support panel
next to the input power cable. Connect the cable to the ground terminal block on the power supply rear panel.
Refer to the Ground Connections Section for full details and procedures on proper system grounding.
PILO
T
WOR
K
TO
RCH
Input power cable
Ground Terminal Block
Connections Cover
Support Panel
System Ground Cable
Art # A-07659_AB
to Remote Arc Starter
Connections Cover
Connection Panel
Leads Bracket
to Remote Arc Starter
AC IN
PUT
System Ground Cable
Input power cable ground
L1
L2
L3
L1
L2
L3
5. Re-install the connections cover on the power supply. Snug the hardware securely by hand. Do not over-
tighten.