beautypg.com

D661a - addendum specs, Data brochure addendum, D 661a – tekmar 661 Snow Detector & Melting Control User Manual

Page 9: D 662a, Additions to technical specifications for type 661, Additions to technical specifications for type 662, Snow detector & melting control 662, Snow detector & melting control 661, Surface, melting, Surface, idling

background image

Snow Detector & Melting Control 662

Literature

— D 662, A 662, D 001, D 090, E 000, E 021, E 600

Control

— Microprocessor PID control; This is not a safety (limit) control.

Packaged weight

— 4.1 lb. (1900 g), Enclosure A, PVC plastic

Dimensions

— 6-5/8” H x 7-9/16” W x 2-13/16” D (170 x 193 x 72 mm)

Approvals

— CSA NRTL/C, meets DOC regulations for EMI/RFI.

Ambient conditions

— Indoor use only, 30 to 105°F (0 to 40°C), < 90% RH non-

condensing.

Power supply

— 120 V ac ±10% 50/60 Hz 300 VA

System Pumps

— 120 V ac 6 A 1/3 hp, pilot duty 240 VA 2 A

Variable Speed Pump — 120 V ac 50/60 Hz 2.2 A 1/6 hp, internally fused
Mix Relays

— 24 V ac 10 A, pilot duty 48 VA 2 A

Other Relays

— 120 V ac 10 A 1/3 hp, pilot duty 240 VA 2 A

Sensors

— NTC thermistor, 10 k

Ω @ 25°C ±0.2°C ß=3892

included:

Outdoor Sensor 070, 3 of Universal Sensor 071, & Slab Sensor 072.

optional:

Snow/Ice Sensor 090 and Sensor Socket 091.

Control accuracy

— ±1°F (±0.5°C) with up to 500 feet (150m) of 18 AWG wire.

Detection of Snow/Ice — Down to -20°F (-29°C) in calm air with 500 feet (150m) of

18 AWG wire to Snow/Ice Sensor 090.

Surface, Melting

— 34 to 44°F (1 to 7°C)

Surface, Idling

— Off, 24 to 35°F (-5 to 2°C)

Water Sensitivity

— 20 to 80%

Maximum Supply

— 100 to 200°F (38 to 93°C)

Min. Boiler Return

— Off, 55 to 150°F (13 to 66°C)

∆T max

— 10 to 50°F (6 to 28°C)

CWCO

— Off, -22 to 25°F (-30 to -4°C)

Motor Speed

— 30 to 230 seconds

Snow Detector & Melting Control 661

Literature

— D 661, A 661, D 001, D 090, E 000, E 600

Control

— Microprocessor PI control; This is not a safety (limit) control.

Packaged weight

— 3.4 lb. (1550 g), Enclosure A, PVC plastic

Dimensions

— 6-5/8” H x 7-9/16” W x 2-13/16” D (170 x 193 x 72 mm)

Approvals

— CSA NRTL/C, meets DOC regulations for EMI/RFI.

Ambient conditions

— Indoor use only, 30 to 105°F (0 to 40°C), < 90% RH non-

condensing.

Power supply

— 120 V ac ±10% 50/60 Hz 20 VA

Relays

— 120 V ac 10 A 1/3 hp, pilot duty 240 VA 2 A

Sensors

— NTC thermistor, 10 k

Ω @ 25°C ±0.2°C ß=3892

included:

Outdoor Sensor 070.

required:

Snow/Ice Sensor 090 and Sensor Socket 091. (Order separately)

Control accuracy

— ±1°F (±0.5°C) with up to 500 feet (150m) of 18 AWG wire

to sensors.

Detection of Snow/Ice

— Down to -20°F (-29°C) in calm air with 500 feet (150m) of

18 AWG wire to Snow/Ice Sensor 090.

Surface, Melting

— 34 to 44°F (1 to 7°C)

Surface, Idling

— Off, 24 to 35°F (-5 to 2°C)

Water Sensitivity

— 20 to 80%

Minimum On Time

— Off, 0.2 to 4 hours

CWCO

— Off, -22 to 25°F (-30 to -4°C)

In North America:

tekmar Control Systems Ltd., Canada
tekmar Control Systems, Inc., USA
Head office:

5100 Silver Star Road

Vernon, B.C. Canada V1

B

3K

4

Tel. (604) 545-7749 Fax. (604) 545-0650

Additions to Technical Specifications for type 661

D 661A

09/94

- Data Brochure Addendum

Snow Detector & Melting Control 661

Pulse Width Modulation

Test

Do not apply power here

H1077 1

Power

Remote

Item

Min. On Time

Sensitivity

Melting

Idling

29

°F

Off

35

24

50%

20

80

Surface

39

°F

34

44

2 hrs

4

Red
Sen

Blk

Sen

Blu

Sen

11 12 13 14 15 16 17 18

Yel

Sen

Brn

Sen

Rem

En

Com

Sen

Out
Sen

1

2

Melt

3

4

Heat

9

10

Pump

Heat

Warning

CWCO

Melting

Idling

WWCO

Water

Target slab

Usage (hours)

Slab

Time Remaining

% Output

To change between

°F and °C, press and
hold for 1 sec.

R

LR 58223

120 V ac

± 10% 50/60 Hz 20 VA

120 V ac 10 A 1/3 hp, pilot duty 240 VA 2 A

Power
Relays

Enclosed Energy Management Equipment

Manufactured

in Canada by

Date
S/N

0694

3005678

Warning

5

6

7

8

Power

L

N

Use Nº 20 AWG or larger copper conductors rated for at least 75

°C / 300V.

The Snow/Ice Sensor is installed in a hostile environment.
It should be cleaned and checked on a regular basis.

N R T L / C

F C

OUTSIDE

CWCO

0

°F

-20

25

Off

Off

0.5

Pump

All specifications are subject to change without notice.

Printed in Canada on recycled paper.

Product designs, software and literature are Copyright © 1994 by:
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.

CAUTION The nonmetallic enclosure does not provide grounding between conduit connections. Use grounding type bushings and jumper wires.
ATTENTION Un boîtier non métallique n'assure pas la continuité électriques des conduits. Utiliser des manchons ou des fils de accord
spécialement conçus pour la mise à la terre.

CAUTION The nonmetallic enclosure does not provide grounding between conduit connections. Use grounding type bushings and jumper wires.
ATTENTION Un boîtier non métallique n'assure pas la continuité électriques des conduits. Utiliser des manchons ou des fils de accord
spécialement conçus pour la mise à la terre.

Additions to Technical Specifications for type 662

D 662A

09/94

- Data Brochure Addendum

Snow Detector & Melting Control 662

Floating / Variable Speed / 4-20 mA

Test

Do not apply power here

H1

1002

Power

Remote

Item

Max. Supply

30

130 sec

230

Motor Speed /

Pump Response

CWCO

10

30

°F

50

∆T Max.

Sensitivity

Melting

Min. Boil Return

Idling

29

°F

Off

35

24

50 %

20

80

Surface

39

°F

34

44

100

°F

Off

150

60

150

°F

100

200

0

°F

-20

25

Red
Sen

Blk

Sen

Blu

Sen

17

18 19 20 21 22 23 24 25 26 27 28

Yel

Sen

Brn

Sen

Com

Sen

Rem

En

Bret
Sen

Com

Sen

Ret

Sen

Sup
Sen

Out
Sen

1

2

Melt

3

4

Boiler

11 12 13 14 15 16

4-20

+

Pump 1

Pump 2

Opening

Boiler

Warning

Closing

CWCO

Melting

Idling

WWCO

Maximum

∆T

Maximum
Supply

Minimum
Return

Water

Supply

Usage (

∆T x hrs)

Slab

Boiler Return

Actual

∆T

% Output

To change between

°F and °C, press and

hold for 1 sec.

R

LR 58223

120 V ac 50/60 Hz 300 VA
120 V ac 6 A 1/3 hp, pilot duty 240 VA 2 A
120 V ac 50/60 Hz 2.2 A 1/6 hp, internally fused
24 V ac 10 A, pilot duty 48 VA 2 A
120 V ac 10 A 1/3 hp, pilot duty 240 VA 2 A

Power
System Pumps
Variable Pump
Mix Relays
Other Relays
Enclosed Energy Management Equipment

Manufactured

in Canada by

Date
S/N

tekmar

motor

Opn

Mix

Cls
Mix

Warning

5

6

9

7

8

P1

Pmp

P2

Pmp

Com
Pmp

Power

L

N

Var

Pmp

Use Nº 20 AWG or larger copper conductors rated for at least 75

°C / 300V

Target

∆T

The Snow/Ice Sensor is installed in a hostile environment.
It should be cleaned and checked on a regular basis.

10

Off

N R T L / C

F C

OUTSIDE

29

Com

Mix

1000

4-20

2094
1234567