GOSSEN Foto- und Lichtmeßtechnik
8.1.1 Measuring correction values 
Correction values can also be measured directly. 
An evenly illuminated surface and constant light 
level are required.
Use the Starlite in the reflected light mode at 
1° or 5°.
In the function 
, a reference measurement
can be taken by pressing the measuring button
.
Designation rF - - in the digital display.
Then, hold the filter in front of the viewfinder and 
press the measuring button 
.
The light reducing effect will be indicated automa-
tically in the display as EV stop and extension 
factor. 
8.1.2 Deleting correction values
In the function 
correction values (chapter 8.1,
page 27) you have two possibilities of deleting 
pre-programmed correction values:
– by manually resetting using the setting wheel to 
EV 0 and extension factor 1.0 or
– by pressing the measuring button
(display rF - -)
– quit the correction value function using the
function button (
or
)
Correction value is deleted.
Symbol 
has disappeared from the display.