5.4

Contrast measuring
in the t and EV functions

Contrast of the subject
Reflected light measuring
through the viewfinder

– Keep the measuring button

pressed

and focus on the various areas of the subject to
be measured.

– The first measuring value appears on the left

digital display. It is constantly displayed as a
reference value (e.g. measurement on a grey
chart) during the course of the entire measuring
process. The actual measuring value flashes
on the analogue scale.

– After releasing the measuring button

, the

measured subject contrast range appears on
the analogue scale.

Illumination contrast
with flat or spherical diffuser

– Keep the measuring button

pressed to

measure the different light sources.

– The first measuring value appears on the left

digital display. It is constanly displayed as a
reference value (e.g. main light source) during
the course of the entire measuring process.
The actual measuring value flashes on the
analogue scale.

– After you release the measuring button

,

the total illumination contrast measured
appears on the analogue scale.