Gossen Starlite User Manual
Page 25
GOSSEN Foto- und Lichtmeßtechnik
25
6.4
Average value
– Take first measurement using measuring
button
– Measure up to a further 8 flashes using the
average value measuring button
.
The individual measurements are shown on
the analogue scale (identical values are only
displayed once, but are taken into account in
the calculation of the average value).
After each measurement with
, the average
value of all previous measurements is always
displayed. The average value AVR is shown in
the digital display:
at the left
with fine adjustment in 1/10 stop
increments and shown as a flashing mark
in the analogue scale, rounded to the nearest
1/2 f-stop. However, the ambient light portion
is not indicated.
In the centre of the display, the number of
measurements M taken is indicated (in the
example 4 measurements).