GOSSEN Foto- und Lichtmeßtechnik
17
5.2
Exposure time priority
– Press the measuring button
to take a
measurement.
– The measured f/stop appears on the left digital
display (resolution in 1/10 stop increments) and
is marked on the analogue scale, rounded to
1/2 stop increments.
– Select other paired f/stop-exposure time values
with the setting wheel.
– Instead of the full exposure time values,
also 1/2 time values can be set by activating
DIP switch 2.
5.3
Exposure value EV
– Press the button
to measure.
– The measured exposure value EV
appears on the left digital display
(resolution in 1/10 stop increments) and
the f/stop is marked additionally on the
analogue scale rounded to 1/2 stops.
– Select other paired f/stop-exposure time values
with the setting wheel.