GOSSEN Foto- und Lichtmeßtechnik

After each measurement using the measuring but-
ton

the following data are stored and displayed:

– the symbol ZONE and the last measured value

are displayed on the left

– the number of measurements made are

displayed on the right (4 measurements in the
example)

– on the zone scale the currently measured

values are indicated (identical values only
once) and the average of the brightest and
the darkest spot as a flashing dot

When the measuring process is completed and
you then switch over to the function „ambient light“

and the desired measuring function, the value

measured in the zone V is displayed as shutter
speed/f-stop combination. Additionally, the flashing
ZONE symbol is displayed.
Now, you can select further shutter speed/f-stop
combinations using the setting wheel.

If, by mistake, you take a zone measurement in
the incident light mode (flat or spherical diffuser),
you are reminded by the flashing diffusor symbol

that you have to set the diffuser ring to 1° spot

metering.
Note down the subject contrast for the film
development and adjust the development time in