7000 control start-up procedures – Watts Fleck 7000 Plastic Valve User Manual
Page 8
Set Time of Day
• Press the Set Up and Set Down buttons to set time of day.
— Metric = 2 hour clock
— US = 12 hour clock with PM indicator light
7000 Control Start-Up Procedures
Page 8
Enter Control Programming Mode
— Press and hold both the Set Up and Set Down buttons for 5 seconds to enter
Programming Mode. When the program mode is entered, the program dot turns on.
The 7000 controller performs 5 basic types of Regeneration systems. The type of system is selected by the sys-
tem manufacturer and set in the Master Programming Mode. Basic systems are:
• Time Clock
— The control operates for a preset number of days between Regeneration cycles. On the day that a
Regeneration cycle is required the system regenerates at the preset Regeneration Time.
• Meter Immediate
— The control regenerates immediately when the remaining capacity (volume of water that can be
treated before a Regeneration is required) drops to 0.
• Meter Delayed
— The control regenerates on the day that the remaining capacity drops to less than the reserve volume.
Regeneration starts at the preset Regeneration Time.
• Meter Delayed - Variable Brining
— The control regenerates on the day that the available volume of softened water drops to or below the
reserve volume. Regeneration starts at the set Regeneration Time. With the variable brining option
activated, the time setting for Cycle 1 is automatically calculated based on the volume of treated water
at the time of regeneration. Cycle time 1 will not exceed the original time setting and is never less than
1 minute.
• Day of the Week
— The control regenerates at the scheduled Regeneration Time on the day(s) of the week which are set
by the user.
The Current Day of the Week display will alternate with the Time of Day when the control is In Service.
The Day of the Week display will increment each day at 12:00 A.M. (Midnight).