Programming a Meter Delayed Regenerated System
Page 10
3. EXTENDED Programming Mode
Regeneration Cycle Step Programming (Display Code 1 to 6)
Use this feature to program the Regeneration Cycle step times. The Regeneration Cycle Step being
programmed appears in the first digit of the display. Each display is used to set the duration time in minutes of
that specific step in the regeneration cycle.
Example:
Cycle Step
dF
dFFF
FLtr
1
10 = Backwash
12 = Fill
10 = Backwash
2
60 = Brine Draw
60 = Brine Making
10 = Rapid Rinse
3
5 = 2nd Backwash
10 = Backwash
10 = Rapid Rinse
60 = Brine Draw
5
12 = Refill
5 = 2nd Backwash
6
10 = Rapid Rinse
— Use the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button to advance to the extended diagnostics.
4. EXTENDED Diagnostics Mode (Viewable Only)
(Dy xx) Display Code xx = days since last Regeneration
— Press the Extra Cycle button once to advance to the next diagnostics.
.
(xxxx) No Display Code xxxx = volume used since the last Regeneration.
.
(yyyy) No display code yyyy = Reserve Volume.
— Press the Extra Cycle button once to Exit Extended Setup Programming Mode.
Control Programming Complete