Programming a day of the week regenerated system – Watts Fleck 7000 Plastic Valve User Manual
Page 15
Page 15
Programming a Day of the Week Regenerated System
1. Extended Programming Mode
Regeneration Cycle Step Programming (Display Code 1 – 6)
Use this feature to program the Regeneration Cycle step times. The Regeneration Cycle Step being
programmed appears in the first digit of the display. Each display is used to set the duration time in minutes
of that specific step in the regeneration cycle.
Example:
Cycle Step
dF
dFFF
FLtr
1
10 = Backwash
12 = Fill
10 = Backwash
2
60 = Brine Draw
60 = Brine Making 10 = Rapid Rinse
3
5 = 2nd Backwash
10 = Backwash
10 = Rapid Rinse
60 = Brine Draw
5
12 = Refill
5 = 2nd Backwash
6
10 = Rapid Rinse
— Use the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button once to proceed to the next step.
— Set to 1 or 0 using the Set Up and Set Down buttons (1 enables a regeneration for that day; 0 disables
a regeneration for that day).
— Press the Extra Cycle button once to exit Setup Programming mode.