beautypg.com

Programming a time clock regeneration system – Watts Fleck 7000 Plastic Valve User Manual

Page 13

background image

Page 13

Programming a Time Clock Regeneration System

3. Extended Programming Mode

Regeneration Cycle Step Programming (Display Code 1 – 6)

This Program Step is used to program the Regeneration Cycle step times. The Regeneration Cycle Step

being programmed is displayed in the first digit of the display. Each display is used to set the duration time in

minutes of that specific step in the Regeneration cycle.

Example:

Cycle Step

dF

dFFF

FLtr

1

10 = Backwash

12 = Fill

10 = Backwash

2

60 = Brine Draw

60 = Brine Making 10 = Rapid Rinse

3

5 = 2nd Backwash

10 = Backwash

10 = Rapid Rinse

60 = Brine Draw

5

12 = Refill

5 = 2nd Backwash

6

10 = Rapid Rinse

— Use the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button once to proceed to the diagnostics.

4. Extended Diagnostics Mode (Viewable Only)
.

(Dy xx) Display Code xx = days since last Regeneration.

— Press the

Extra Cycle button once to advance to the next diagnostics.

.

(xxxx) No Display code xxxx = the volume used since the last Regeneration

— Press the Extra Cycle button once to Exit Extended Setup Programming Mode.

Control Programming Complete