Time Clock or Day of the Week Regeneration Valves

In normal operation the Time of Day Display may be viewed at all times. The control operates for a preset

number of days between Regeneration cycles. When the number of days since the last Regeneration reaches

the preset number of days, a Regeneration cycle initiates at the preset Regeneration Time.

Program the number of days between Regeneration cycles and the Regeneration time using the 7000 Control

Start-Up Procedures.

Flow Meter Equipped Valves – General

Flow meter equipped valves calculate the volume of water that the system can treat between Regeneration

cycles based on the system capacity which is preset by the system manufacturer in a Master Programming

Mode and the feed water hardness which is programmed in the Start-Up procedure safety factor (Master

Mode only).

The remaining system capacity displays in gallons or liters. The display has a range of 0 to 9999 (gallons or

liters). If the remaining capacity exceeds 9999 liters when in the Metric Mode, then the display changes to

millions of liters and a letter t is displayed as the first digit. The display then has a range of t1.0 (1,000,000) to

t1.9 (1,900,000).

Flow Meter Equipped Valves – Immediate Regeneration Mode

The Time Of Day display alternates with the Volume Remaining display in gallons or liters. The Meter dot

flashes in direct relation to the water flow rate through the unit. As treated water is used, the Volume Remain-

ing display counts down from a maximum value to zero and initiates a Regeneration cycle immediately.

7000 Control Operation and Settings

Page 6

Display

Program Indicator

Programming Mode Active, Light On

In Service Indicator

Valve In Service, Light On

Manual Regeneration Qued, Flashing Light

Flow Indicator

Water Flow, Light Flashing

P.M. Indicator/Valve Moving Light Flashing

P.M., Light On

A.M., Light Off

Display Screen

Time of Day alternates with Process Display

(for example, Volume Remaining, Time Remaining,

Programming Information), Error Codes

Set Down Button

Adjust Values Down

Set Up Button

Adjust Values Up

Extra Cycle Button

User-Initiated and Program Step Advance Regeneration