beautypg.com

Programming a meter immediate regeneration system – Watts Fleck 7000 Plastic Valve User Manual

Page 11

background image

1. Feed water hardness (Display Code H)

The feed water hardness setting displays only if the system is set to operate as a Meter Immediate or Meter

Delayed system type.

— Press the Set Up and Set Down buttons to set the amount of feed water hardness (grains/gallon or

degrees). The system automatically calculates treated water capacity based on the feed water hardness

and the system capacity preset in the Master Programming mode.

Example:

Range: 4 – 199 US and Metric

— To program 9 grains / gallon (US) or 9 degrees (Metric) [H – 9]

— Press the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button once to Exit Setup Programming Mode or press and hold the Set Up and

Set Down buttons simultaneously for five (5) seconds to enter the Extended Setup Programming Mode.

Programming a Meter Immediate Regeneration System

Page 11

2. EXTENDED Programming Mode
.

Regeneration Cycle Step Programming (Display Code 1 – 6)

This Program Step is used to program the Regeneration Cycle step times. The Regeneration Cycle Step

being programmed is displayed in the first digit of the display. Each display is used to set the duration time in

minutes of that specific step in the Regeneration cycle.

Example:

Cycle Step

dF

dFFF

FLtr

1

10 = Backwash

12 = Fill

10 = Backwash

2

60 = Brine Draw

60 = Brine Making 10 = Rapid Rinse

3

5 = 2nd Backwash

10 = Backwash

10 = Rapid Rinse

60 = Brine Draw

5

12 = Refill

5 = 2nd Backwash

6

10 = Rapid Rinse

This manual is related to the following products: