beautypg.com

Connecting the circuit board – Watts Fleck 7000 Plastic Valve User Manual

Page 30

background image

Page 30

Connecting the Circuit Board

1

41033C

DF253-0

A

A1

C1

4

C

3

B1

B

2

41033-2

DF254-0

D2

D1

After the circuit board is installed:
1. Connect the motor wires (A) to the motor connector (A1) on board.
2. Connect the transformer cable (B) to the transformer connector (B1) on board.
3. Connect the meter cable (C) to the meter cable connector (C1) on board.
. Connect the meter cable sensor end to the opening on the valve body.
5. Thread meter cable (D1) and power wire (D2) along path shown in above illustration.

This manual is related to the following products: