Dimensions, Hookups – Banner U-GAGE T30U—Level Control User Manual
Page 6

with Rod Target (Typical)
0
50
50
100
100
150
150
200
200
0
200 mm
(8.0 in)
400 mm
(16.0 in)
600 mm
(24.0 in)
800 mm
(32.0 in)
1000 mm
(40.0 in)
0
2.0 in
2.0 in
4.0 in
4.0 in
6.0 in
6.0 in
8.0 in
8.0 in
25 mm Rod
10 mm Rod
DISTANCE
WIDTH
(mm)
Figure 9. 1-Meter Models
0
100
100
200
200
300
300
400
400
DISTANCE
0
400 mm
(16.0 in)
800 mm
(32.0 in)
1200 mm
(48.0 in)
1600 mm
(64.0 in)
2000 mm
(80.0 in)
0
4.0 in
4.0 in
8.0 in
8.0 in
12.0 in
12.0 in
16.0 in
16.0 in
25 mm Rod
WIDTH
(mm)
Figure 10. 2-Meter Models
Dimensions
M30 x 1.5
Thread
ø 40.0 mm
(1.57")
Cabled Models
Quick-Disconnect Models
Jam Nut
(Supplied)
45.0 mm
(1.77")
ø 15 mm
(0.59")
11.5 mm
(0.45")
51.5 mm
(2.03")
66.5 mm
(2.62")
Hookups
Shield*
12-24V dc
–
+
1
3
2
4
5
Remote
Teach
Output 1
Output 2
Figure 11. Cabled NPN
Shield*
12-24V dc
–
+
1
3
2
4
5
Remote
Teach
Output 1
Output 2
Figure 12. Cabled PNP
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
Cable and QD hookups are functionally identical.
It is recommended that the shield wire is connected to earth ground or dc common.
U-GAGE® T30 Series with Dual Discrete Outputs
6
www.bannerengineering.com - tel: 763-544-3164
P/N 059200 Rev. E