Dimensions, Hookups, Accessories – Banner U-GAGE T30U—Level Control User Manual
Page 7: Cordsets
Dimensions
M30 x 1.5
Thread
ø 40.0 mm
(1.57")
Cabled Models
Quick-Disconnect Models
Jam Nut
(Supplied)
45.0 mm
(1.77")
ø 15 mm
(0.59")
11.5 mm
(0.45")
51.5 mm
(2.03")
66.5 mm
(2.62")
Hookups
Shield*
12-24V dc
–
+
1
3
2
4
5
Remote
Teach
Output 1
Output 2
Figure 9. Cabled NPN
Shield*
12-24V dc
–
+
1
3
2
4
5
Remote
Teach
Output 1
Output 2
Figure 10. Cabled PNP
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
Cable and QD hookups are functionally identical.
It is recommended that the shield wire is connected to earth ground or dc common.
Accessories
Cordsets
5-Pin Threaded M12/Euro-Style Cordsets with Shield
Model
Length
Style
Dimensions
Pinout
MQDEC2-506
1.83 m (6 ft)
Straight
44 Typ.
ø 14.5
M12 x 1
2
3
4
1
5
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
MQDEC2-515
4.57 m (15 ft)
MQDEC2-530
9.14 m (30 ft)
MQDEC2-550
15.2 m (50 ft)
MQDEC2-506RA
1.83 m (6 ft)
Right-Angle
32 Typ.
[1.26"]
30 Typ.
[1.18"]
ø 14.5 [0.57"]
M12 x 1
MQDEC2-515RA
4.57 m (15 ft)
MQDEC2-530RA
9.14 m (30 ft)
MQDEC2-550RA
15.2 m (50 ft)
U-GAGE® T30U Series Sensors - Pump-In/Pump-Out
P/N 063974 Rev. C
www.bannerengineering.com - tel: 763-544-3164