SSYSTEM INSTALLATION GUIDE

www.redwoodsystems.com

13

IMPORTANT NOTES

The Engine requires 6 inches or more clearance for the fans to operate properly.
Ensure that air vents are not blocked and that the conditions support the maximum ambient

operation temperature listed in the Engine Specification Sheet.

4.3 Install Redwood Director

Director is a 1U rack mountable system and can be installed in a standard server rack via supplied rack-
mounting brackets. A Redwood Director is required when you have a cluster of between 8 and 128
Engines. It connects to the network and manages the cluster via Ethernet.

4.4 Connect Redwood Low-Voltage Cabling (Category Cabling Option)

Category 5e or 6/6a cabling can be used to connect Redwood Engines to Redwood Gateways. Use the
Redwood Patch Cord to make the connection from the Engine to the patch panel; category cable is then
run from the patch to the gateway.

Each Redwood Patch Cord should be connected from a bank on the front of the Engine to a patch panel,
which is connected to respective Redwood Gateways and Wall Switches. Each Redwood Patch Cord will
provide connection for up to 8 ports/channels.

An example is depicted below, showing the punch down of Category 5 cable at the back of a patch panel
that connects to the LED Gateway.

Example connecting Redwood Engine to Patch Panel using the Redwood RJ45 Patch Cable