Average power, Match measurement, Figure 7 match measure uncertainty – Bird Technologies 5019D-Manual User Manual
Page 30: Average power match measurement, 18 average power, Measurement range: return loss rho

18
Average Power
RF Power Range
0.15 – 150 W
Peak/Average Ratio, Max
12 dB
Measurement Uncert.
± (4% of reading ± 0.05 W)
a
a. Above 35 °C or below 15 °C add 3%
Match Measurement
Measurement Range:
Return Loss
Rho (
)
VSWR
0 to 23 dB
0.07 to 0.999
1.15 to 99.9
Forward Power, Min
.5 W
Measurement Uncert.
See Figure
Figure
7
Match Measure Uncertainty
-6
-4
-2
0
2
4
-25
-20
-15
-10
-5
0
Un
certai
n
ty
(d
B)
Return Loss
Above
3GHz+
Above
3GHz-
Below
3GHz+
-6
-4
-2
0
2
4
-5
0
Un
certai
n
ty
(d
B)
Power Supply:
DPM
USB Port
DC Connector
From host instrument via cable
Less than one low-power USB load
7 – 18 Vdc, < 100 mA
Data Logging
In VPM Software
This manual is related to the following products: