beautypg.com

Input center conductor assembly – Bird Technologies 8630B Series User Manual

Page 48

background image

Bird 8630B Series Moduload RF Load Resistor

32

1. Turn the load on end, with the RF input connector up, to allow

debris, if present, to fall out of the load housing.

2. Loosen and remove the 1/4-20 x 5/8 inch hex head screws from the

flanged end of the load housing assembly as shown in Figure 9.

3. Remove the outer conductor assembly.
4. Remove the input center conductor assembly by pulling it out of

the load housing assembly.

Input Center

Conductor

Assembly

Refer to Figure 10 while following the instructions below.

Model 8730A, (used in the Model 8635 and 8635B), 1-5/8 inch EIA
flanged input connector only.

1. Remove the 1/4-20 x 3/4 inch pan head machine screw and 1/4

inch split lockwasher by unscrewing the screw while holding the

center conductor stationary.

2. Remove the center conductor, the center conductor adapter, and

the insulator from the rest of the assembly.

3. Remove the resistor fitting by pushing the exposed end of the

fitting into the outer flow tube. The resistor fitting and any broken

pieces of resistor will fall from the opposite end of the outer flow

tube.

4. Inspect all O-Ring seals, metal and internal parts for damage. The

metal parts may be discolored or oxidized and may be cleaned by

rubbing them with fine abrasive cloth or silver cleaner. The Teflon

parts can be cleaned with detergent and water. If any of the

internal parts are damaged, they must be replaced to ensure

proper electrical and/or thermal performance of the load.

5. Insert the replacement resistor into the resistor fitting. If the

fitting is loose press the slotted finger contacts of the fitting

together slightly and try the resistor again. Continue this

procedure until a snug fit is obtained.

6. Reassemble the center conductor assembly by first replacing the

outer flow tube seal O-Ring. If needed, insert the resistor and

resistor fitting in position in the outer flow tube.

7. Replace Insulator center conductor adapter, and center conductor.

Tighten in place with 1/4-20 x 3/4 Inch pan head machine screw

and 1/4 inch split lockwasher.