Bird 8630B Series Moduload RF Load Resistor

24

10. Note the positions of the fittings. Observe the slight downward tilt

of the 90° input elbow. Twist off, counterclockwise, the whole input

and output fittings parts. Remove the small drain elbow also. Store

the detached parts with the disassembled unit and return the

pump/motor unit to the factory for replacement.

11. Replace the pump/motor and assemble the unit by reversing the

disassembly procedure above. Refill the unit with coolant per the

instructions in the Coolant section.

CAUTION

Do not remove any fittings from the water chamber. The elbows

could be damaged, and may be difficult to restore them to their

original positions while keeping a water-tight seal. Check the

switch for free operation. Flush and clean with mild detergent of

necessary, and rinse thoroughly in clear water.