beautypg.com

Model 8638 and 8638b, Preliminary equipment check, Meter rack – Bird Technologies 8630B Series User Manual

Page 29: Preliminary equipment check meter rack

background image

Installation

13

Model 8638 and

8638B

Model 8638 and 8638B - 3-1/8" unflanged, 50 ohm impedance. Refer
to Figure 5 while following the instructions below.

1. Use the Bird Coupling Kit P/N 5-726, consisting of two clamping

bands, an outer sleeve, and the center conductor coupling bullet.

2. Insert the center bullet, and bottom it on the midpoint nibs.
3. Position the outer sleeve, with clamps, over the input connector.
4. Introduce the transmission line and seat snugly against the

coupling stops.

5. Position clamp bands evenly about 1-3/4" apart, and tighten.

Preliminary

Equipment Check

Check the RF load for acceptable electrical condition. Refer to the
Maintenance Chapter for the procedure to determine load impedance.
Below is the test equipment needed, and the critical parameters.

Equipment Needed: Digital Multimeter

Accuracy: 1 percent at 50 ohms, ± 1 digit

Meter Rack

The Meter Rack is used to hold the meter at the correct angle, for the
best possible viewing. Assemble and install as instructed below:

1. Assemble the kit using #6-32 x 1/4 screws, (supplied).
2. Remove the 2 screws from the panel at a desired mounting

location.

3. Mount the assembled Meter Rack using #8-32 x 3/8 phillips truss

(supplied). Refer to Figure 6.

Figure 5

Connecting RF

Power Model 8638

and 8638B

RF Coaxial Line

Clamping Bands

Connector Sleeve

Bullet

RF Load Connector