beautypg.com

Chapter 5 maintenance, Troubleshooting, Chapter 5 - maintenance. if a – Bird Technologies 8630B Series User Manual

Page 33: Maintenance

background image

Maintenance

17

Chapter 5

Maintenance

This chapter covers cleaning, inspection, trouble-shooting, and
specifications for the 8630 and 8630B Series Moduload RF Load
Resistors.

Troubleshooting

The table below provides troubleshooting information for problems
which may occur during normal operation. Locate the problem,
review the possible causes, and perform the action listed. This
manual cannot list all malfunctions that may occur, or their
corrective actions. If a problem is not listed or is not corrected by the
listed actions, notify a qualified service center.

PROBLEM

POSSIBLE CAUSE

CORRECTION

Transmitter won’t
come on or shuts off
repeatedly

Insufficient coolant flow

Check coolant gauge

Check for blockage in circulatory system

Check for coolant leaks

Defective flow switch

Check flow switch

Defective pump

Check pump

Overheating

Check for sufficient coolant

Defective thermoswitch

Check thermoswitch

Check for excessive room temperature

Check fans for jamming and grilles for
blockage

Excessive reflected
power

Damaged resistor

Check resistance value of RF section

Contaminated coolant

Drain, flush and refill coolant system

Insufficient coolant

Check for coolant leaks and add more
coolant

Coolant Leaking

Loose connections

Check and tighten all connections

Worn or cracked tubing

Replace defective tubing

New or unusual
noises

Fans

Check for loose fan blades

Pump

Check pump for signs of initial failure

Circulatory system

Check for any sign of coolant leakage