Chapter 5 maintenance, Troubleshooting, Chapter 5 - maintenance. if a – Bird Technologies 8630B Series User Manual
Page 33: Maintenance
Maintenance
17
Chapter 5
Maintenance
This chapter covers cleaning, inspection, trouble-shooting, and
specifications for the 8630 and 8630B Series Moduload RF Load
Resistors.
Troubleshooting
The table below provides troubleshooting information for problems
which may occur during normal operation. Locate the problem,
review the possible causes, and perform the action listed. This
manual cannot list all malfunctions that may occur, or their
corrective actions. If a problem is not listed or is not corrected by the
listed actions, notify a qualified service center.
PROBLEM
POSSIBLE CAUSE
CORRECTION
Transmitter won’t
come on or shuts off
repeatedly
Insufficient coolant flow
Check coolant gauge
Check for blockage in circulatory system
Check for coolant leaks
Defective flow switch
Check flow switch
Defective pump
Check pump
Overheating
Check for sufficient coolant
Defective thermoswitch
Check thermoswitch
Check for excessive room temperature
Check fans for jamming and grilles for
blockage
Excessive reflected
power
Damaged resistor
Check resistance value of RF section
Contaminated coolant
Drain, flush and refill coolant system
Insufficient coolant
Check for coolant leaks and add more
coolant
Coolant Leaking
Loose connections
Check and tighten all connections
Worn or cracked tubing
Replace defective tubing
New or unusual
noises
Fans
Check for loose fan blades
Pump
Check pump for signs of initial failure
Circulatory system
Check for any sign of coolant leakage