Bird 8630B Series Moduload RF Load Resistor
22
Model 8638 and 8638B — unflanged, loosen one clamping band on
the load side of the connector sleeve. Refer to Figure 5.
3. Separate the transmission coaxial air line from the load connector.
Make sure the center conductor bullet remains in the transmission
line.
To remove the load resistor unit take off the top panel by removing
the 18 screws around its perimeter. Lift off the top panel assembly by
the handles. Continue following these instructions:
1. Remove, and retain the drain plug located near the bottom of the
rear panel of the unit and allow the coolant to drain.
Note: Do not replace the drain plug with any substitute plug, use
the plug removed.
2. Unscrew the hose clamps on the hoses leading to the input elbow of
the flow switch and the output elbow on the water chamber. Use
an ordinary screwdriver.
3. Remove the hoses.
4. On the 8630, loosen the hex collar on the flow switch assembly and
remove the collar and sensor from the flow switch body. On the
8630B, disconnect the flow switch wires at their in-line connectors.
The output elbow on the side of the water chamber can now be
removed by unscrewing counterclockwise.
5. Remove the six 1/4-20 x 5/8 hex head bolts (on the inside of the
front panel) securing the load to the front panel.
Note: When the six bolts securing the load to the front panel are
removed the outer conductor assembly will be disconnected. Hold this
assembly to keep it from falling and being damaged.
6. Temporarily reattach the outer conductor to the load body. Use
two or three of the 1/4-20 bolts (finger tight) for this purpose.
7. Tip up the the unit at the back enough to unscrew the flow switch
counterclockwise. The input elbow on the water chamber can be
taken off after the load is removed through the front panel.
8. If the load resistor is to be returned to the factory for repair, store
components with the Moduload unit until further use. Consult the
factory. If the unit is to be field repaired, proceed with resistor
replacement instructions as described in the Internal Repair of the
Load Resistor section.
9. Replace the load resistor by reversal of the above procedure. Be
sure to replace the coolant, per the coolant section. Check for leaks,
especially at the restored connections.