background image

Maintenance

49

magnitude is subtracted from the magnitude of the
measurement signal. For relatively small interferers
(i.e. interfering signal smaller than the measurement
signal), this technique yields approximately 10 dB bet-
ter rejection. If the interfering signal becomes larger
than the measurement signal, the correction output
approaches zero, corresponding to a perfect match.
Measurement results are not accurate under these cir-
cumstances. The remedy is to disable the interfering
source, if possible, or postpone the measurement to a