beautypg.com

Rockwell Automation 2LW3000 LonWorks Communication Option Module for VTAC 7 Drives User Manual

Page 34

background image

3-20

LonWorks Module for VTAC 7 Drives

3.5

Installing the LonWorks Module in 15 to 25 HP and
25 to 60 HP @ 460VAC Drives

Use this procedure to install the LonWorks module in the drives listed in table 3.6.

Refer to figure 3.12 or 3.13 as you perform the procedure.

Unless otherwise indicated, keep all hardware that is removed. You will need it for
reassembly. This includes screws, lock washers, and rivets.

If the drive is panel-mounted, this procedure will be easier to perform if the drive is
removed from the panel.

!

ATTENTION: Only qualified electrical personnel familiar with the
construction and operation of this equipment and the hazards involved
should install, adjust, operate, or service this equipment. Read and
understand this manual and other applicable manuals in their entirety
before proceeding. Failure to observe this precaution could result in
severe bodily injury or loss of life.

ATTENTION: The drive is at line voltage when connected to incoming
AC power. Disconnect, lock out, and tag all incoming power to the drive
before performing the following procedure. Failure to observe this
precaution could result in severe bodily injury or loss of life.

ATTENTION: DC bus capacitors retain hazardous voltages after input
power has been disconnected. After disconnecting input power, wait five
minutes for the DC bus capacitors to discharge and then check the
voltage with a voltmeter to ensure the DC bus capacitors are discharged
before touching any internal components. Failure to observe this
precaution could result in severe bodily injury or loss of life.

ATTENTION: The drive contains ESD- (Electrostatic Discharge)
sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing the drive. Erratic machine
operation and damage to, or destruction of, equipment can result if this
procedure is not followed. Failure to observe this precaution can result
in bodily injury.

Table 3.6 – Model Numbers for 15 to 25 HP and 25 to 60 HP @ 460 VAC Drives

Model Numbers for 15 to 25 HP

VTAC 7 Drives

Model Numbers for 25 to 60 HP

VTAC 7 Drives

15H41xx
15H42xx

25W21xx

20H41xx
20H42xx

30H41xx
30H42xx

25H41xx
25H42xx

40H41xx
40H42xx

50H41xx
50H42xx

60H41xx
60H42xx