Installing the LonWorks Module in the Drive

3-5

Step 4.

Install the LonWorks Module in the Keypad Bracket

Refer to figure 3.2 for component locations.

Step 4.1 Remove the LonWorks module from its anti-static wrapper. Align the key on

the Regulator board’s 34-conductor ribbon cable connector with the slot in
the LonWorks module’s connector. Press the ribbon cable connector in until
it locks into position.

Step 4.2 Route the 26-conductor ribbon cable for the Current Feedback board out of

the side of the keypad bracket.

Step 4.3 Align the LonWorks module on the four mounting tabs on the keypad

bracket. Make sure that the ribbon cable is not pinched between the keypad
bracket and the LonWorks module.

!

ATTENTION: The drive contains ESD- (Electrostatic Discharge)
sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing the drive. Erratic machine
operation and damage to, or destruction of, equipment can result if this
procedure is not followed. Failure to observe this precaution can result
in bodily injury.

Figure 3.2 – LonWorks Module Location in 1 to 5 HP @ 460 VAC Drives

Side View

Front View

Top View

Regulator
Board

20

16

REVERSE

AUTO

REMOTE

RUNNING

FORWARD

RPM

Password

TORQUE

Kw

Hz

JOG

AMPS

VOLTS

PROGRAM

PROGRAM

AUTO

Reverse

JOG

RUN

ENTER

START

RESET

STOP

Forward

LonWorks
Module

Current Feedback
Board

LonWorks
Module