Installing the LonWorks Module in the Drive
3-5
Step 4.
Install the LonWorks Module in the Keypad Bracket
Refer to figure 3.2 for component locations.
Step 4.1 Remove the LonWorks module from its anti-static wrapper. Align the key on
the Regulator board’s 34-conductor ribbon cable connector with the slot in
the LonWorks module’s connector. Press the ribbon cable connector in until
it locks into position.
Step 4.2 Route the 26-conductor ribbon cable for the Current Feedback board out of
the side of the keypad bracket.
Step 4.3 Align the LonWorks module on the four mounting tabs on the keypad
bracket. Make sure that the ribbon cable is not pinched between the keypad
bracket and the LonWorks module.
!
ATTENTION: The drive contains ESD- (Electrostatic Discharge)
sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing the drive. Erratic machine
operation and damage to, or destruction of, equipment can result if this
procedure is not followed. Failure to observe this precaution can result
in bodily injury.
Figure 3.2 – LonWorks Module Location in 1 to 5 HP @ 460 VAC Drives
Side View
Front View
Top View
Regulator
Board
20
16
REVERSE
AUTO
REMOTE
RUNNING
FORWARD
RPM
Password
TORQUE
Kw
Hz
JOG
AMPS
VOLTS
PROGRAM
PROGRAM
AUTO
Reverse
JOG
RUN
ENTER
START
RESET
STOP
Forward
LonWorks
Module
Current Feedback
Board
LonWorks
Module