Contactor enable and power connector pinouts – Rockwell Automation 2093-AMxx Kinetix 2000 Integrated Axis Module and Axis Module Installation Instructions User Manual
Page 8
8 Kinetix 2000 Multi-axis Servo Drives
Rockwell Automation Publication 2093-IN001B-EN-P - July 2013
Connector Descriptions
Contactor Enable and Power Connector Pinouts
These connectors are supplied with removable wiring plugs. The pins are numbered
consecutively from top to bottom.
Contactor Enable (CED) Connector
Control Power (CPD) Connector
Designator Description
Connector
BC
Motor brake
4-position plug/header
CED
(1)
(1)
Connector is only on integrated axis modules (catalog numbers 2093-AC05-MP
x).
Contactor enable
2-position plug/header
CPD
(1)
Control input power (drive)
2-position plug/header
DPI
(1)
Drive peripheral interface (factory use only)
8-pin mini-DIN
IOD/AF
User I/O (drive) and auxiliary feedback
44-pin high-density D-shell (female)
IPD
(1)
230V AC input power (drive) and DC bus
6-position plug/header
MF
Motor feedback
15-pin high-density D-shell (female)
MP
Motor power
4-position plug/header
Tx and Rx
SERCOS transmit and receive
SERCOS fiber-optic (2)
IMPORTANT
These connectors are available only on integrated axis modules (catalog numbers
2093-AC05-MP
x).
CED Pin
Description
Signal
1
Relay-driven dry contact used in the safety string for a three-phase power
contactor.
CONT EN+
2
CONT EN-
CPD Pin
Description
Signal
1
Control power VAC input line 1
CTRL 1
2
Control power VAC input line 2
CTRL 2