Iod/af and mf signal wiring – Rockwell Automation 2093-AMxx Kinetix 2000 Integrated Axis Module and Axis Module Installation Instructions User Manual
Page 13

Kinetix 2000 Multi-axis Servo Drives 13
Rockwell Automation Publication 2093-IN001B-EN-P - July 2013
IAM and AM Module Power Wiring Requirements
IOD/AF and MF Signal Wiring
Refer to the Kinetix Motion Accessories Specifications Technical Data, publication
servo drives.
Connector
Connects to Terminals
Recommended Wire and Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
Pin Signal
Brake
BC-1
BC-2
BC-3
BC-4
PWR
BRK+
BRK-
COM
Solid H05(07) V-U: 0.75 (18)
Stranded H07 V-R: 0.75 (18)
Flexible H05(07) V-K: 0.75 (18)
Flexible with ferrule 0.75 (18)
7.0
(0.28)
0.5
(4.4)
Motor
MP-1
MP-2
MP-3
MP-4
Motor power cable depends on
motor/drive combination
2.5 (14)
7.0
(0.28)
0.5
(4.4)
U
V
W