Chapter 4
OCR Tool Configuration
4–2
To create an OCR Tool, choose Tools from the menu on the Toolset image
display panel. The following panel appears allowing you to add a new OCR
Tool or copy an existing one:
The following are brief descriptions of the Toolset Edit panel. Refer to the
CVIM2 Reference Manual (Catalog No. 5370-801) for detailed information
on editing a toolset.
Num
The sequence number of an inspection tool. it indicates the order in which
the CVIM2 system processes the tool number. The currently selected tool is
marked by an arrow.
Name
The inspection tool name. All tools are provided a default tool number such
as Tool 1. Clicking on the current name displays the keyboard for entering a
new name.
Type
The inspection tool type such as OCR. Clicking the tool type box for a tool
displays the edit panel for that tool.
Enabled
Indicates whether the tool is enabled, Yes or No. Yes is the default.
Ref
Use this field to select a reference tool for the purpose of providing shift
and/or rotation compensation for the selected inspection tool.
S1
use this field to select the primary image source for a tool from a camera
(such as C1) or from an image buffer (such as P1).
S2
Secondary image column is not applicable since OCR2 works with only one
image source.
Dst
Indicates the destination of the image. P1 is the default for an OCR Tool
indicating that the destination is a processed image.
Adding an OCR Tool