beautypg.com

Appendix b, Set up the touchscreen interface, Touchscreen serial interface – Rockwell Automation 6186-Mxxx Industrial Monitors User Manual User Manual

Page 53: Appendix b - touchscreen serial interface, Appendix

background image

Publication 6186M-UM001J-EN-P - July 2008

53

Appendix

B

Touchscreen Serial Interface

All touch controllers are configured by default to provide serial
communication at 9600 baud, 8 data bits, 1 stop bit, and no parity.

For monitors equipped with touchscreens, a serial 2 m (6 ft)
communication cable is included. You can also create your cable. The
cable is a straight-wired serial (RS-232) cable with a male DB-9 D-shell
connector on the monitor end.

The cable provides a communication channel between the
touchscreen controller, which is mounted inside the monitor, and an
RS-232-C serial port on the host computer. Because the touch
controller obtains power from the monitor’s power supply, no
external touch-power connections are necessary.

Software supplied with the touchscreen must be loaded on the host
computer to handle communications with the touch controller over
the channel.

Because the touchscreen emulates a mouse, there may be
compatibility issues involving how the touchscreen emulates mouse
buttons, especially multiple buttons. For a complete discussion of
these issues and how to troubleshoot them, refer to the touchscreen
documentation.

Set Up the Touchscreen
Interface

This section describes how to set up the touchscreen system. You will:

enable the touchscreen interface.

install the software on the host computer that will handle
communications with the touchscreen controller.

calibrate a touchscreen.