7, installing optional single-user dps software, 0 installing the optional singlećuser dps software – Rockwell Automation AutoMax Prog Exec V4.2 and Dist. Power System Drive Software Install User Manual
Page 19

7Ć1
7.0 INSTALLING THE
OPTIONAL SINGLEĆUSER
DPS SOFTWARE
The singleĆuser DPS software is required for programming,
monitoring, and loading operating systems to DPS drives. Five
model numbers are available: M/N 57C651, 57C652, 57C653,
57C654, and 57C655.
Each model number contains the software required for one drive
product and its associated regulators and must be installed
separately. The singleĆuser Executive software must be installed
before the singleĆuser DPS software.
Use the following procedure to install the DPS software options, one
at a time.
Step 1.
To begin installing the DPS software, insert the disk
labeled 1" in floppy drive A: or B:.
Click Start, then click Run, and then type:
ą
where:
ą
ąthe disk.
Click OK" to begin the install procedure.
Before installing any files, the install program will display two
messages. The first message describes the type of installation
(SingleĆUser); the second lists the number of disks required for the
install procedure and the amount of hard disk space required for the
DPS software.
Step 2.
You will be prompted for the drive and subdirectory in
which to install the DPS software. The defaults are as
follows:
ą
where:
ą
ą
ą
You can make changes to any of the above parameters. Note that
the DPS software must be installed in the same directory as the
Executive software.
Step 3.
If a UDC task skeleton file (SKELETON.UDC) is found in
the install directory, the install procedure will display a
message stating that the existing UDC task skeleton file
(SKELETON.UDC) has been reĆnamed to
USKELTON.UDC.
The install procedure will install a new task skeleton file
(SKELETON.UDC). After the install procedure is completed, you
must update the new skeleton file with any custom information from
your old skeleton files (USKELTON.UDC), and then delete the old
skeleton file. If you are installing multiple DPS software options,
update the new skeleton file after all options have been installed.