Using RSView ME Station 4-3

Other Shortcut Paths for RSView ME Station

• To run the .MER application and delete its log files without

replacing the terminal’s communication configuration with that
of the applications, use the following path:

Path to MERuntime.exe, followed by a space, followed by the path
to the .MER, followed by /r/d

To run the .MER application and replace the terminal’s
communication configuration with that of the applications
without deleting its log files, use the following path:

Path to MERuntime.exe, followed by a space, followed by the path
to the .MER, followed by /r/o

• To run the .MER application, delete its log files, and replace the

terminal’s communication configuration with that of the
applications, use the following path:

Path to MERuntime.exe, followed by a space, followed by the path
to the .MER, followed by /r/d/o

IMPORTANT

If the path to RSView ME or the path to the application
contains spaces, you must enclose the path in double
quotes.

Example:

"Flash Storage\Rockwell Software\RSViewME\MERuntime.exe" "Flash Storage\Rockwell Software\RSViewME\Runtime\MYAPP.MER" /r/d

Example:

"Flash Storage\Rockwell Software\RSViewME\MERuntime.exe" "Flash Storage\Rockwell Software\RSViewME\Runtime\MYAPP.MER" /r/o

Example:

"Flash Storage\Rockwell Software\RSViewME\MERuntime.exe" "Flash Storage\Rockwell Software\RSViewME\Runtime\MYAPP.MER" /r/d/o