58 Configure the RSLinx Ethernet Communication Driver

1. Start RSLinx.

2. From the Communications menu, select Configure Drivers.
3. From the Available Driver Types drop down menu, select Ethernet

Devices, and then click Add/New.
The Add New RSLinx Driver dialog box appears.

4. Select the default driver name (for example, AB_ETH-1) or type in your

own name and click OK.
The Configure driver dialog appear with the Station Mapping tab open.

5. Click Add New and enter the IP address or Host Name of your Ethernet

device (for example, 130.130.130.2, “Pump1”).

6. Repeat step 5 for each additional Ethernet device you need to access.