beautypg.com

Rockwell Automation 2092-DAx Ultra1500 Digital Servo Drive Quick Start User Manual

Page 12

background image

12 Ultra1500 Digital Drives Quick Start

Publication 2092-QS001D-EN-P — July 2005

Continuous Power
Overload

Motion application requires average
drive power in excess of rated capability

• Reduce acceleration rates.

• Reduce duty cycle (ON/OFF) of

commanded motion.

• Increase time permitted for motion.

• Use larger drive and motor.

• Check tuning.

Encoder Type Mismatch

Motor encoder signals do not match
drive configuration

Verify motor selection.

Defective encoder

Replace motor.

Encoder Communication
Error

Wiring between drive and encoder is
faulty or disconnected, or EMI (noise)
disrupts encoder signals.

• Verify encoder wiring.

• Contact A-B.

Special Communication
Error

Communications error between host and
drive (noise)

• Verify serial cable.

• Check for noise on serial interface.

Position Command
Frequency Error

Input frequency limit exceeded

• Verify hardware type selected in the drive

matches the physical hardware.

• Change from open collector to line drive.

• Reduce the speed command.

• Apply gearing.

Error

Code

Text
Message

Possible Cause

Action/Solution