beautypg.com

Editing the program with quick edit, Offline config – Rockwell Automation 9323-PA1E QUICK START GUIDE APS 6.0 User Manual

Page 47

background image

Online Operations, Quick Edit

4–7

Editing the Program with Quick Edit

The quick edit feature of APS software allows you to move quickly from online
monitoring to offline editing, then back to online monitoring. To give you
experience at doing this, we will edit the program by adding an input instruction on
the rung. The effect of the edit: Selector switch 6 must be on (closed) to allow
pushbutton 0 to turn on pilot light 0.

We will place an XIC instruction in series with (to the right of) the XIC instruction
already entered. It will have address I:2/2, corresponding to selector switch 6 of the
demo unit. See the figure below.

( )

O:3

0

] [

I:1

0

] [

I:2

2

Add this instruction

Complete the following six steps to edit and test the edited program. The starting
point for this procedure is the online monitor file display, with the processor in the
run mode:

Press a function key

(file 2, rung 0)

REM RUN

no forces

PROC Addr 1

F2

CONFIG

DISPLAY

F9

FORCE

END

F10

EDIT

F3

EXIT

F6

F7

SEARCH

GENERAL

UTILITY

( )

O:3

0

] [

I:1

0

Input pushbutton turns on output pilot light

F8

DATA

MONITOR

F1

CHANGE

MODE

F5

DOCUMNT

1.

Go offline and edit the disk version of the file.

Press

CONFIG

OFFLINE

CONFIG

EDIT

F10

, then

CONFIG

OFFLINE

CONFIG

OFFLINE

DISK

F3

. Note that the status line of the display now

indicates that you are offline, at file GETSTART.