Start-up Information Messages
Start-up information messages display in a specific sequence on the terminal during
startup and typically display for a few seconds. These messages do not require that
you perform any action.
Message #
Message
Description
37
Video Initialized
Configures and initializes the graphics video system.
30
Watchdog Test
Tests the watchdog circuitry to verify system integrity.
1
RAM Test
Tests the RAM memory.
31
Stuck Key
Checks the integrity of the function key hardware.
31.5
Stuck Touch
Checks the integrity of the touch screen hardware.
32
Battery Test
Checks the integrity of the battery hardware.
2.5
Registry Search
Locates and loads the most recent, valid registry. Multiple copies of
the registry are maintained. If power is lost during a registry update, a
valid registry is available the next time power is applied to the
terminal.
2
Image Search
Checks for a new OS firmware upgrade on the external CompactFlash
card and the serial port.
50
External CF
Transfers a new OS firmware upgrade from the external
CompactFlash card to the terminal. Message may display for several
minutes.
23
Internal CF
Programs the OS firmware just downloaded into the internal flash
memory. Message may display for several minutes.
24
CRC Check
Checks the integrity of the OS firmware.
28
Starting System
Launches the operating system (OS).
29
System Check ###
Internal file system integrity check (### is percent progress indicator).
29.1
System Check
Internal file system integrity check disabled. Contact technical
support.