Rockwell Automation 57C445 AutoMax PC Link Interface Module User Manual
Page 15
3Ć3
Table 3.1 - Port Locations and DIP Switch Settings (Continued)
0x0638
ON
OFF
OFF
ON
ON
ON
0x0640
ON
OFF
ON
OFF
OFF
OFF
0x0648
ON
OFF
ON
OFF
OFF
ON
0x0650
ON
OFF
ON
OFF
ON
OFF
0x0658
ON
OFF
ON
OFF
ON
ON
0x0660
ON
OFF
ON
ON
OFF
OFF
0x0668
ON
OFF
ON
ON
OFF
ON
0x0670
ON
OFF
ON
ON
ON
OFF
0x0678
ON
OFF
ON
ON
ON
ON
0x0680
ON
ON
OFF
OFF
OFF
OFF
0x0688
ON
ON
OFF
OFF
OFF
ON
0x0690
ON
ON
OFF
OFF
ON
OFF
0x0698
ON
ON
OFF
OFF
ON
ON
0x06A0
ON
ON
OFF
ON
OFF
OFF
0x06A8
ON
ON
OFF
ON
OFF
ON
0x06B0
ON
ON
OFF
ON
ON
OFF
0x06B8
ON
ON
OFF
ON
ON
ON
0x06C0
ON
ON
ON
OFF
OFF
OFF
0x06C8
ON
ON
ON
OFF
OFF
ON
0x06D0
ON
ON
ON
OFF
ON
OFF
0x06D8
ON
ON
ON
OFF
ON
ON
0x06E0
ON
ON
ON
ON
OFF
OFF
0x06E8
ON
ON
ON
ON
OFF
ON
0x06F0
ON
ON
ON
ON
ON
OFF
0x06F8
ON
ON
ON
ON
ON
ON
Note: These port locations are the only I/O addresses recognized by
the AutoMax Programming Executive software.
If you are not using the PC Link module with the AutoMax
Programming Executive software, any of the addresses listed in Table
3.1 are possible, although other equipment in the personal computer
may conflict with the address chosen. Keep in mind that the I/O
space required is 8 bytes, so a setting of 250 actually uses ports
250Ć257.
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (2 pages)
- 100 Contactors with DC Coil (1 page)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)